nixos/spdk: Move to SPDK 26.09
SPDK 26.01 crashes while scanning the PCI bus with DPDK 26.07. Pick
up the fork's bump to SPDK 26.09, which adds the 26.07 compatibility
layer, and drop the 26.01-only DPDK 26.03 workaround.

SPDK 26.09 sizes transport caches from the shared iobuf pool, so the
RDMA transport on `cellar` starved the bdev and accel caches. Set its
caches explicitly and enlarge the pools. Also retry `spdk-tgt` on
failure, as loading its config can fail intermittently at startup.

Co-Authored-By: Claude Opus 5.5 <noreply@anthropic.com>
2026-11-22 15:11:44 +00:00

161 lines
4.8 KiB
Nix

{ lib, pkgs, config, assignments, ... }:
let
inherit (lib) mapAttrsToList;
in
{
config = {
boot.blacklistedKernelModules = [ "nvme" ];
systemd.services = {
spdk-tgt.after = [ "systemd-networkd-wait-online@lan-hi.service" ];
};
my = {
spdk = {
enable = true;
extraArgs = "--mem-channels 2 --cpumask 0xffff";
# `spdk-debug` exposes the RAID as /dev/ublkb1 (e.g. to edit its partition table)
debug.ublkDisks = [ "NVMeRaid" ];
config.subsystems =
let
nvmeAttaches = mapAttrsToList (name: bdf: {
method = "bdev_nvme_attach_controller";
params = {
hostnqn =
"nqn.2014-08.org.nvmexpress:uuid:2b16606f-b82c-49f8-9b20-a589dac8b775";
trtype = "PCIe";
inherit name;
traddr = bdf;
};
}) {
"NVMe0" = "02:00.0";
"NVMe1" = "03:00.0";
"NVMe2" = "04:00.0";
};
nvmfListener = nqn: {
method = "nvmf_subsystem_add_listener";
params = {
inherit nqn;
listen_address = {
adrfam = "IPv4";
traddr = assignments.hi.ipv4.address;
trsvcid = "4420";
trtype = "RDMA";
};
secure_channel = false;
};
};
nvmfBdev = { nqn, hostnqn, bdev, serial }: [
{
method = "nvmf_create_subsystem";
params = {
inherit nqn;
serial_number = serial;
};
}
(nvmfListener nqn)
{
method = "nvmf_subsystem_add_host";
params = {
inherit nqn;
host = hostnqn;
};
}
{
method = "nvmf_subsystem_add_ns";
params = {
inherit nqn;
namespace = {
bdev_name = bdev;
nsid = 1;
};
};
}
];
in
{
# Sized with `scripts/calc-iobuf.py` for the 16-core mask: the bdev and accel caches
# plus the RDMA transport's, with headroom for in-flight I/O
iobuf = [
{
method = "iobuf_set_options";
params = {
small_pool_count = 16384;
large_pool_count = 2048;
};
}
];
scheduler = [
{
method = "framework_set_scheduler";
params.name = "dynamic";
}
];
bdev = [
{
method = "bdev_set_options";
params.bdev_auto_examine = false;
}
] ++ nvmeAttaches ++ [
{
method = "bdev_raid_create";
params = {
base_bdevs = [ "NVMe0n1" "NVMe1n1" "NVMe2n1" ];
name = "NVMeRaid";
raid_level = "raid0";
strip_size_kb = 64;
};
}
{
method = "bdev_examine";
params.name = "NVMeRaid";
}
{ method = "bdev_wait_for_examine"; }
];
nvmf = [
{
method = "nvmf_create_transport";
params = {
trtype = "RDMA";
# The default takes whatever the shared pool has left, starving the other caches
iobuf_small_cache_size = 32;
iobuf_large_cache_size = 32;
};
}
(nvmfListener "nqn.2014-08.org.nvmexpress.discovery")
] ++ (nvmfBdev {
bdev = "NVMeRaidp1";
nqn = "nqn.2016-06.io.spdk:river";
hostnqn =
"nqn.2014-08.org.nvmexpress:uuid:12b52d80-ccb6-418d-9b2e-2be34bff3cd9";
serial = "SPDK00000000000001";
}) ++ (nvmfBdev {
bdev = "NVMeRaidp2";
nqn = "nqn.2016-06.io.spdk:castle";
hostnqn =
"nqn.2014-08.org.nvmexpress:uuid:2230b066-a674-4f45-a1dc-f7727b3a9e7b";
serial = "SPDK00000000000002";
}) ++ (nvmfBdev {
bdev = "NVMeRaidp3";
nqn = "nqn.2016-06.io.spdk:sfh";
hostnqn =
"nqn.2014-08.org.nvmexpress:uuid:85d7df36-0de0-431b-b06e-51f7c0a455b4";
serial = "SPDK00000000000003";
}) ++ (nvmfBdev {
# `slop-cannon`'s disk; `palace` connects it and hands it to the VM
bdev = "NVMeRaidp4";
nqn = "nqn.2016-06.io.spdk:slop-cannon";
hostnqn =
"nqn.2014-08.org.nvmexpress:uuid:a5b573fe-59e0-4760-802d-4b6d2df6dcf2";
serial = "SPDK00000000000004";
});
};
};
};
};
}